# 7. Remote viewing: installing Ring Remote View

*Canonical HTML version: https://ring-rs3000.pages.dev/docs/installer/07-remote-view.html*

*Screenshot: The Ring Remote View login page in a browser. (https://ring-rs3000.pages.dev/assets/shots/app/remote-view-01-login.png)*

**Authority for this chapter:** `docs/production-readiness/REMOTE_ACCESS_RUNBOOK.md`
and `remote-view/README.md`, cross-checked against the installer scripts
themselves. Where the two disagree with a 2026-09-04 bench verification pass,
this chapter follows the bench pass and says so — see
[Status and what is still owed](#status) at the end.

## What it is and what it is not {#what-it-is}

Ring Remote View is a separate, optional package. It is not part of Ring,
and it is not a second copy of Ring.

What it actually does: it lets someone on the plant or office LAN open a
browser, log in, and watch — or, for a small named list of accounts, drive —
the **one** Ring session already running on the HMI PC. It mirrors that one
screen. It does **not** start a second Ring process, does **not** open a
second connection to the controller, and no Ring file — no `.cs`, no
`.csproj`, no `appsettings*.json`, no build output — is ever read or written
by anything in this package. Installing or removing Ring Remote View cannot
change how Ring behaves. If you uninstall it later, Ring itself never
notices.

Every time someone tries to connect, the operator standing at the panel sees
a **consent prompt** naming who is asking, with **Allow** and **Deny**
buttons. Nobody watches or drives silently. If nobody answers the prompt, it
is refused automatically — an unattended panel denies the connection by
design, it does not quietly let it through. Every desktop session that does
go ahead is recorded to disk on the HMI PC as evidence, not just logged as
an event.

What operators themselves see and are expected to do when a consent prompt
appears is covered from their side, not the installer's, in the operator
manual — see [operator manual, 10. Remote viewing](../operator/10-remote-viewing.md).

This chapter installs the **LAN-only** version: reachable only from inside
the plant's own network, with no exposure to the internet at all. Getting an
engineer connected from home, or a vendor connected from off-site, is a
second, separate, additive install covered in
[chapter 7a, Remote viewing off-site](07a-remote-view-off-site.md) — do not
run anything from that chapter until this one is fully installed and
verified.

## Decide before you start {#before-you-start}

This is a new inbound network surface on a live plant PC, even though it is
scoped tightly. Three sign-offs are required before you run anything below —
get them in writing, not just a nod on the floor:

- [ ] **Plant POC** — blesses a new inbound surface on the HMI PC, and
  confirms the office LAN range you'll use for `-LanCidr`.
- [ ] **Controls engineer** — confirms that console mirroring, with an
  operator consent prompt, during live batching is acceptable, and agrees
  the "who's driving" etiquette with the shift teams (see
  [Give people access](#accounts) below for the rights model that etiquette
  relies on).
- [ ] **IT / security** — accepts a self-signed certificate on the LAN (or
  supplies a real one afterward), and accepts the antivirus allow-list step
  below.

### Survey the machine {#survey-the-machine}

Walk the HMI PC through this table before you copy anything to it:

| Item | What you need | Why it matters |
|---|---|---|
| Hostname | Resolvable on the office LAN; no `@`, `/` or `:` characters | The self-signed certificate's name is built from this hostname (see [Right after install](#after-install)) |
| Windows version | Windows 10 1803 or later, or Windows 11 — **x64 only** | The package ships a win-x64 Node and MeshCentral agent only |
| Free disk on `C:` | At least 2 GB free | The payload is roughly 108 MB zipped and unpacks to roughly 394 MB on disk, plus room for recordings |
| Office LAN IPv4 + CIDR | e.g. `192.168.10.0/24` | This is the `-LanCidr` value below |
| Plant/PLC NIC | A **different physical NIC** from the office LAN, if this PC has one | See [Firewall and network category](#firewall) — a dual-homed PC needs extra parameters |
| Office NIC network category | **Domain** or **Private** — never **Public** | A Public-classified NIC makes the firewall rule silently inert; see [Firewall and network category](#firewall) |
| AV / EDR product + version | Recorded, and IT notified in advance | See the allow-list note below |
| Windows Firewall managed by GPO? | Yes / no | If yes, the domain admin adds the rule, not you |
| Local admin account | Available | The installer requires an elevated session throughout |
| PowerShell version | **5.1** (the target) | Every script here is 5.1-compatible; `pwsh` is not required, and was not exercised in any bench pass reviewed here |

### The antivirus allow-list step {#antivirus-allow-list}

MeshCentral's own agent binaries are commonly flagged by antivirus and EDR
products as remote-management ("RMM") tooling. That is an accurate
description of what the software is, not a false positive to argue with —
raise it with IT **before** install day, as its own sign-off item, rather
than debugging a quarantined agent on the floor afterward.

On a Windows Defender machine, the observed detection family is
**`HackTool:Win32/Meshagent`** — seen quarantining the packaging machine's
`MeshService64.exe`, `MeshCmd64.exe` and `MeshCentralAssistant.exe` while the
payload was being built. The same family of binary was already quarantined on the install target
too, ahead of the 2026-09-04 bench pass — Defender's detection history
there showed the staged agent binary (`MeshService.exe`, under
`C:\Program Files\Mesh Agent\`) quarantined on 2026-08-20 as RMM tooling.
Without an exclusion for that folder, the 2026-09-04 install would have
failed on it; the exclusion was added before the install ran. Ask IT for
an exclusion covering `C:\Ring\RemoteView\` and `C:\Program Files\Mesh
Agent\` ahead of time.

### Do not install if {#do-not-install-if}

- The cutover is mid-flight and the plant POC has not signed off above.
- The HMI PC cannot be rebooted or serviced in the coming maintenance
  window — the install itself needs a few minutes of exclusive access and
  restarts a Windows service.
- You are installing at an actual customer site and haven't checked the
  current state of the outstanding items in
  [Status and what is still owed](#status) — the full penetration test this
  package's own runbook treats as a hard gate is not yet complete end to
  end.

## Get the package {#get-the-package}

Get the package one of these three ways.

**Option A — download it from this site.** The password-protected download
page of this documentation site (the `/download` page, the same one that
carries the Ring release) has a section named **"Ring Remote View (optional
companion)"** with the zip's size and SHA-256. Ask whoever gave you the Ring
release password; it is the same password. The zip contains the
`remote-view\` folder with every script, `config-template.json`, the
licences, the built payload (`remote-view\dist\RingRemoteView-payload.zip`
with `manifest.json` and `payload-inventory.json` beside it), and the three
remote-access runbooks under `docs\`. You do not need Node.js or internet
access on the HMI PC; everything the server needs is inside that zip.

The zip is about 109 MB, so use the same part-wise downloader the Ring
release uses (see [chapter 2a](02a-remote-install-over-vpn.md)), pointed at
this package. It signs in, fetches six verified parts, joins them and checks
the final hash, and it is safe to re-run if a part fails:

```powershell
Invoke-WebRequest https://ring-rs3000.pages.dev/get-ring.ps1 -OutFile get-ring.ps1
powershell -ExecutionPolicy Bypass -File .\get-ring.ps1 -Manifest remoteview.json -Destination C:\RingDownload
```

The page also has a one-click **"Download Ring-RemoteView-20260904.zip"**
link that streams the same parts as one file. On a slow link that stream can
stop early without an error, so if you use it, check the hash against the
page before you copy anything to the HMI PC, and fall back to the script if
it does not match:

```powershell
Get-FileHash .\Ring-RemoteView-20260904.zip -Algorithm SHA256
```

**Option B — get it from engineering.** The package lives as the
`remote-view/` folder inside the `merged_code` repository (see engineering
manual, [9.5 Remote access](../engineering/09-build-deploy-release.md#95-remote-access)).
Ask engineering for a copy of that folder, already built — that is, including
`dist\RingRemoteView-payload.zip` and `dist\manifest.json`.

**Option C — build it yourself**, on any dev box with PowerShell, Node.js
and npm on `PATH`, and internet access to `registry.npmjs.org` and
`nodejs.org`:

```powershell
cd merged_code\remote-view

# Prove the fetch logic first - resolves versions and HEAD-probes the
# download URLs, downloads nothing.
.\Build-RemoteViewPackage.ps1 -ProbeOnly

# Real build (roughly 480 MB fetched, pruned down, then zipped).
.\Build-RemoteViewPackage.ps1
```

`-ProbeOnly` resolves the newest active Node LTS line and confirms
MeshCentral's pinned version and the download URLs all answer, without
pulling anything — a quick way to prove the packaging machine can actually
reach what it needs before committing to the full download. The real build
downloads a portable Node LTS runtime and MeshCentral 1.2.4, installs the
extra startup modules MeshCentral needs on Windows, prunes the agent
binaries down to Windows x64 only, and writes `dist\manifest.json` (the
software bill of materials — hand this to a customer's AV/EDR team
alongside the allow-list request above) and `dist\RingRemoteView-payload.zip`.
The result is roughly 394 MB staged, zipping to roughly 108 MB; both the
exact sizes and every file's SHA-256 are recorded in `dist\manifest.json`,
not repeated here. If the packaging machine's own antivirus quarantines a
required agent binary mid-build, the build fails loudly rather than
shipping a payload that can't start — add a Defender exclusion for the
build's output directory and rebuild.

Either way, copy the **whole** `remote-view\` folder to the HMI PC,
including `dist\RingRemoteView-payload.zip` **and** `dist\manifest.json`
sitting next to it — the installer verifies the archive's checksum against
that manifest before it unpacks a single file, and without it that check
degrades to a warning instead of a hard stop.

## Install {#install}

From an **elevated** PowerShell session on the HMI PC, in the folder you
copied:

```powershell
.\Install-RemoteView.ps1 `
    -AdminUser ringadmin `
    -LanCidr 192.168.10.0/24 `
    -Operators @(
        @{ User = 'jbaker';    ViewOnly = $false },   # may drive
        @{ User = 'shiftlead'; ViewOnly = $true  }    # watch only
    )
```

`-AdminUser` is the site administrator — this account stays with plant
management and is never handed to an operator (see
[Give people access](#accounts) for why). Each entry in `-Operators` is one
person's account; `ViewOnly = $false` means that account can drive the
console, `ViewOnly = $true` (the default if you omit the key) means
watch-only. Every parameter is described in full below — for the exact
numeric rights masks and every other pinned constant behind these flags, see
[reference, 9. Remote View reference](../reference/09-remote-view-reference.md).

### Every installer parameter {#install-parameters}

| Parameter | Default | What it does |
|---|---|---|
| `-AdminUser` | `ringadmin` | Site administrator account id. Stays with plant management, never handed to operators. |
| `-AdminPassword` | *(none)* | `SecureString`. Omit this and `-AdminPasswordFile` and a 20-character password is generated and printed once. |
| `-AdminPasswordFile` | *(none)* | Path to a UTF-8 file whose first line is the admin password. Read into memory and the file is deleted immediately, so the password never sits on a command line or in a setup log. |
| `-LanCidr` | auto-detected `/24` | The allowed LAN range, e.g. `192.168.10.0/24`. **Required together with `-InterfaceAlias`** on a multi-homed machine — the installer refuses to guess. |
| `-InterfaceAlias` | *(none)* | The office/LAN NIC name the firewall rule binds to. **Required together with `-LanCidr`** on a dual-homed HMI PC, so the rule can never land on the plant/PLC NIC. |
| `-HttpsPort` | `8443` | Pinned. Change only for a real, documented reason — the firewall rule name and every shortcut are built from this value. |
| `-Operators` | `@()` | Array of hashtables: `@{User='jbaker'; Pass='...'; ViewOnly=$true}`. `ViewOnly=$true` = watch only; `$false` = may drive — see [reference, 9. Remote View reference](../reference/09-remote-view-reference.md) for the exact rights masks. |
| `-OperatorSpec` | *(none)* | Flat alternative to `-Operators`: `"jbaker:control,shiftlead:view"`. Written for the Inno Setup GUI wrapper — which has never actually been compiled; see [Status](#status). |
| `-PayloadZip` | `<script dir>\dist\RingRemoteView-payload.zip` | The built payload archive. |
| `-PayloadDir` | *(none)* | Alternative to `-PayloadZip`: an already-expanded payload folder. |
| `-InstallRoot` | `C:\Ring\RemoteView` | Pinned install location. |
| `-NoFirewall` | off | Skip creating the inbound firewall rule. Staging/lab installs only — a normal plant install needs the rule. |
| `-NoAgent` | off | Skip installing the local Mesh Agent service. Server-only staging installs only. |
| `-Reinstall` | off | Adopt-and-replace an existing service pair instead of aborting. See below for exactly what this resets. |
| `-TempExpandRoot` | `$env:TEMP` | Where the payload is expanded before it's copied in. Only needs changing if `%TEMP%` is so deep a path would exceed `MAX_PATH` — the installer checks this itself and tells you if so. |
| `-VerifyPayloadHashes` | off | Additionally re-hashes every extracted file against the build's file inventory. Off by default — it costs several minutes on an HMI laptop with on-access antivirus scanning every file. |
| `-HealthTimeoutSeconds` | `180` | How long to wait for the server to answer on `https://127.0.0.1:<port>` before giving up. |

### What it does, in order {#install-order}

1. Stages the payload and proves it is complete (see below) before copying
   a single file into the install root.
2. Confirms the runtime modules MeshCentral needs at startup are present.
3. Renders `config.json` from `config-template.json` — including a
   lowercase, dotted certificate name and an explicit list of allowed
   browser origins built from this machine (see
   [Right after install](#after-install) for why both of those matter).
4. Creates the site administrator account offline, then reads the account
   database back to confirm it actually holds full site-admin rights.
5. Installs and starts the **MeshCentral** Windows service, which
   generates the self-signed certificate itself on first start, then polls
   `https://127.0.0.1:<port>/` until the server answers healthy.
6. Provisions the **Plant HMI** device group and every operator account,
   and reads each one's rights mask back from the server to confirm it
   landed exactly as intended.
7. Installs the local **Mesh Agent** service, background-only — there is
   no interactive "connect" button on the HMI PC itself, only the consent
   prompt described above.
8. Adds the inbound firewall rule (unless `-NoFirewall`), scoped as
   described in [Firewall and network category](#firewall).
9. Creates the Start Menu and desktop shortcuts, then prints the summary
   below.

### What you will see {#what-you-will-see}

The install prints a running commentary, then a summary block. These lines
are excerpted from a real bench install — your own hostname, IP and
passwords will differ:

```
Administrator account confirmed as site administrator (siteadmin=4294967295).
Server is healthy.
Server certificate present: subject=CN=laptop-t8d4hur8.local (self-signed, generated on first start).
Certificate name : laptop-t8d4hur8.local   (settings.cert; must contain a dot or MeshCentral offers no two-factor login)
allowedOrigin    : laptop-t8d4hur8, laptop-t8d4hur8.local, localhost, 127.0.0.1, 192.168.1.206
...
PROVISIONING OK

  New operator credentials (shown ONCE - hand them over in person, do not email):
    jbaker              <20-character password>   (one-time; must be changed at first login)
    shiftlead           <20-character password>   (one-time; must be changed at first login)

  Every account must enrol an authenticator app at first login (domain force2factor is on).
...
INSTALL OK

  URL              : https://laptop-t8d4hur8:8443/
  Install root     : C:\Ring\RemoteView
  Services         : "MeshCentral" (server), "Mesh Agent" (local agent)
  Firewall         : TCP 8443 inbound, LocalSubnet, ALL interfaces - no interface filter was applied (no -InterfaceAlias given).
  WARNING          : the chosen NIC is classified Public. The rule profile is Domain,Private, so it will NOT apply until the NIC is re-classified Private/Domain.
  Device group     : "Plant HMI" (features 4 = record sessions, consent 9 = notify + prompt)
  Admin account    : ringadmin

  ADMIN PASSWORD (shown once, store it with plant management, do NOT give it to operators):
    <20-character password>
```

The **`WARNING`** line about a Public-classified NIC only appears when it
applies — see [Firewall and network category](#firewall) for what it means
and how to fix it before you assume the install failed. Both the admin
password and every operator's one-time password are printed exactly once,
to the console — nowhere else. Write them down or capture the console
output now; there is no "show me that again" later.

**Expected duration.** On the bench laptop a full install took a little
under three and a half minutes end to end (measured at 175 and 203 seconds
across two runs, on an NVMe drive with an antivirus exclusion already in
place). Expect longer on an HMI PC where on-access antivirus is actively
scanning the roughly 394 MB payload as it's copied — do not assume a stall
after five minutes is necessarily a hang; check Task Manager for disk
activity before killing it.

**Payload verification, in short.** The archive is never unpacked with
`Expand-Archive` — on Windows PowerShell 5.1 that command can silently drop
files from a payload this size with no error and exit code 0, so the
installer reads the zip entry by entry instead and checks the result
several separate ways: the whole archive's SHA-256 against `manifest.json`,
every entry's path and exact byte length against the archive's own central
directory, every entry again against `manifest.json`'s payload inventory,
and the install root itself re-checked after everything is copied. Any
shortfall stops the install before it copies anything, and
names exactly which files are missing rather than leaving a silently
incomplete server running.

**Rollback, in short.** If any step after that fails, the installer undoes
only what *this run* created — the install root, the config file, both
services, the firewall rule, the shortcuts, and (only when it created a
fresh account database) the accounts — and leaves anything already on the
machine untouched. If an item can't be removed it prints
**`ROLLBACK INCOMPLETE`** and names exactly what is still on disk, rather
than reporting a clean rollback it didn't actually achieve.

### `-Reinstall`: what it resets {#reinstall}

Re-running the installer against a machine that already has a "MeshCentral"
or "Mesh Agent" service on it aborts by default — pass `-Reinstall` to stop
and remove the existing service pair first instead. If this HMI PC still has
its previous `meshcentral-data` folder, that folder — and the account
database inside it — is **preserved**, not recreated, with one exception:
the site administrator's password is reset to match whatever this run's
`-AdminPassword` (or a freshly generated one) is, and that reset clears the
administrator's two-factor enrolment along with it, so the admin has to
enrol an authenticator again at the next login. Existing operator accounts
in that same database keep their own passwords and 2FA enrolment untouched;
only their rights mask is re-asserted against the values you passed.

## Right after install {#after-install}

Do these six things before you consider the install finished, in this
order.

1. **Browse to `https://<hostname>:8443/` — by hostname, not by IP
   address, and not `localhost`.** For example
   `https://ring-hmi-01:8443/` for a PC named `RING-HMI-01`. This matters more than it looks:
   MeshCentral checks the browser's Origin header against an allow-list
   built from this machine's own name, and if you type an address that
   isn't on that list the page loads past login and then shows only
   **"Invalid origin in HTTP request, click to reconnect."** with nothing
   else on the page. This package's certificate name and allow-list are
   built so the bare hostname, the certificate name, the LAN IPv4 address,
   `localhost` and `127.0.0.1` all work — anything else does not (see
   [When something goes wrong](#troubleshooting) if you hit this anyway).
   Trust the self-signed certificate once, the first time each browser
   connects — there is no plant PKI behind it, so this warning is
   expected, not a fault.

2. **Log in as the administrator**, using the one-time password from the
   `INSTALL OK` summary. The first login forces a password change before
   anything else loads:

   <figure class="doc-shot"><img src="../../assets/shots/app/remote-view-02-password-change.png" alt="First login: the one-time password must be changed." loading="lazy"><figcaption>First login: the one-time password must be changed.</figcaption></figure>

3. **Enrol an authenticator app immediately** — every account, including
   the admin, must, because `force2factor` is on domain-wide. Go to **My
   Account → Account security → Manage authenticator app**, scan the QR
   code (or type the secret by hand) into an authenticator app, then enter
   the current 6-digit code it shows to activate it:

   <figure class="doc-shot"><img src="../../assets/shots/app/remote-view-03-2fa-enrol.png" alt="My Account, Account security, Manage authenticator app: scan the code or type the secret, then enter the current 6-digit token." loading="lazy"><figcaption>My Account, Account security, Manage authenticator app: scan the code or type the secret, then enter the current 6-digit token.</figcaption></figure>

   Do this before you click anything else in the interface. Every device
   click is blocked with the message **"Unable to access this feature
   until two-factor authentication is enabled. This is required for extra
   security. Go to the 'My Account' tab and look at the 'Account Security'
   section."** until enrolment is done — enrolling first avoids running
   into that message at all. Every login after this one asks for a fresh
   6-digit code on a second page, not just the password:

   <figure class="doc-shot"><img src="../../assets/shots/app/remote-view-02b-2fa-token.png" alt="Every later login asks for the 6-digit code from the authenticator app." loading="lazy"><figcaption>Every later login asks for the 6-digit code from the authenticator app.</figcaption></figure>

4. **Confirm the HMI PC shows up and is connected.** Open **My Devices**
   and confirm the machine appears in the **Plant HMI** group — on the
   bench it showed the status **"Agent, Powered"**:

   <figure class="doc-shot"><img src="../../assets/shots/app/remote-view-04-devices.png" alt="My Devices: the HMI PC in the Plant HMI group." loading="lazy"><figcaption>My Devices: the HMI PC in the Plant HMI group.</figcaption></figure>

5. **Hand each operator their one-time password in person.** Never by
   email, never by chat — the same rule the runbook applies to the admin
   password applies here. Each one must change it and enrol their own
   authenticator at their own first login, exactly as you just did.

6. **The go-live gate.** Before remote access is announced to the shift,
   open **My Users** in the web UI and confirm **every** provisioned
   account — the administrator and every operator — has actually
   completed authenticator enrolment, not just changed its password.
   Record this by **name and date** in the cutover packet. Do not tell
   anyone remote access is ready, and do not consider this install
   finished, while any provisioned account still shows no authenticator
   enrolled — a password-only account is real, working access with the
   second factor missing, not a harmless loose end.

## Firewall and network category {#firewall}

The installer creates one inbound rule automatically, as the last step
before it prints `INSTALL OK`:

| Port | Direction | Protocol | Scope | Rule name | Why |
|---|---|---|---|---|---|
| **8443** | Inbound | TCP | `LocalSubnet` | `Ring Remote View (HTTPS 8443)` | The web UI — the only inbound surface this package adds |
| **4433** | — | TCP | not listening (no socket on any interface) | **no rule at all** | See below |
| Plant/PLC NIC | Inbound | any | — | **nothing** | Must gain no inbound surface whatsoever |

**Why nothing for 4433.** `4433` is MeshCentral's Intel AMT management port;
the config pins it and would bind it to `127.0.0.1`. But in the LAN-only mode this package ships in,
MeshCentral's own `mpsserver.js` never even starts that listener (it checks
`(args.lanonly != true) && (args.mpsport !== 0)` before opening it) —
confirmed on a bench install, where the machine had no socket bound to 4433
at all, on any interface. There is nothing there to firewall.

**The Public-profile trap.** The rule is created with `Profile =
Domain,Private` on purpose — Windows only applies a rule on interfaces
whose *current* network category matches, so if the office NIC is
classified **Public**, the rule silently does nothing and 8443 is
unreachable, with no error anywhere. This is exactly what the `WARNING`
line in the [install summary](#install) is telling you about if it appears.
Fix the classification, don't work around it:

```powershell
Get-NetConnectionProfile -InterfaceAlias 'Office LAN'
Set-NetConnectionProfile -InterfaceAlias 'Office LAN' -NetworkCategory Private
```

The rule is never created with `Profile = Public` or `Any` — a remote-access
surface must not be advertised on an untrusted network, so re-classifying
the NIC is the only fix, not loosening the rule's profile.

**Dual-homed HMI PCs.** If this machine has a second NIC on the plant/PLC
network, `LocalSubnet` scoping alone is not enough — it would expose 8443
on that network too if the plant subnet is also "local" to Windows. That is
exactly why `-LanCidr` and `-InterfaceAlias` are both required together on a
multi-homed box (see the [parameter table](#install) above); the installer
binds the rule to that one NIC and then re-reads it back to confirm the
binding took. Verify it yourself any time with:

```powershell
Get-NetFirewallRule -DisplayName 'Ring Remote View (HTTPS 8443)' | Get-NetFirewallInterfaceFilter
```

To fix or remove the rule later without a full reinstall, the same script
the installer calls is also there to run by hand:

```powershell
.\New-RemoteViewFirewallRule.ps1                              # default 8443, LocalSubnet
.\New-RemoteViewFirewallRule.ps1 -InterfaceAlias 'Office LAN' # bind to one NIC
.\New-RemoteViewFirewallRule.ps1 -Remove                      # remove it
```

**A rule you did not ask for.** The Mesh Agent's own installer creates a
second inbound rule by itself, named **"Mesh Agent WebRTC Traffic"** — UDP,
any local port, any remote port, scoped to the agent's own executable
(`C:\Program Files\Mesh Agent\MeshAgent.exe`), and — unlike the rule above —
on **all three** firewall profiles, including Public. This package's config
has `webRTC: false`, so the rule is unused, but it exists on disk and a
security reviewer will find it. Either disable it or accept it explicitly as
a documented exception:

```powershell
Disable-NetFirewallRule -DisplayName 'Mesh Agent WebRTC Traffic'
```

Uninstalling Ring Remote View removes this rule too, as a side effect of the
Mesh Agent's own uninstall — see [Uninstall](#uninstall).

## Give people access {#accounts}

To add another operator later, without touching anything else on the
machine, run the provisioning script by itself from the install folder:

```powershell
cd C:\Ring\RemoteView
.\Provision-RemoteView.ps1 `
    -AdminUser ringadmin `
    -AdminPassword (Read-Host 'admin password' -AsSecureString) `
    -Operators @(@{ User = 'nightshift'; ViewOnly = $true })
```

**View-only is the default.** Grant `ViewOnly = $false` (control) per named
person, deliberately, and record who and why — not as a default setting for
a group. This is idempotent: running it again for someone who already has
an account leaves their password alone and simply re-asserts their rights
mask, and a newly created account's one-time password is printed once, the
same as during install — hand it over in person, never by email. The new
person still has to change that password and enrol their own authenticator
at first login. For the exact numeric rights masks and every other pinned
constant this package uses, see
[reference, 9. Remote View reference](../reference/09-remote-view-reference.md).

**To remove someone**, use the web UI: **My Users → select the account →
Delete**. Or, to disable someone's access without deleting their login,
remove only their grant on the **Plant HMI** device group instead. Either
way, deleting the account does **not** delete their past session
recordings — that's intentional. Recordings are evidence, and stay in
`meshcentral-recordings\` regardless of what happens to the account that
made them.

## Check your work {#verify}

- [ ] **Browse from another office PC** (not the HMI PC itself) to
  `https://<hostname>:8443/` and confirm the login page loads and the
  certificate warning is the expected self-signed one.
- [ ] **Log in as the administrator and confirm the 2FA prompt appears** on
  every login after the first — not just once at setup.
- [ ] **Confirm the HMI PC shows as connected** in **My Devices**, group
  **Plant HMI** — on the bench the device list showed the status "Agent,
  Powered".
- [ ] **Connect as an operator account and confirm the consent prompt
  appears at the panel** — the person there should see a dialog naming who
  is asking, with Allow and Deny buttons. This was observed directly on the
  bench: connecting and never answering the prompt left the browser's
  Desktop tab reading **"Waiting for user to grant access..."**,

  <figure class="doc-shot"><img src="../../assets/shots/app/remote-view-05-desktop-waiting.png" alt="Desktop tab after Connect: 'Waiting for user to grant access...' while the person at the panel decides." loading="lazy"><figcaption>Desktop tab after Connect: "Waiting for user to grant access..." while the person at the panel decides.</figcaption></figure>

  while the HMI's own desktop showed the consent dialog itself, naming the
  requesting account:

  <figure class="doc-shot"><img src="../../assets/shots/app/remote-view-06-consent-prompt.png" alt="What the person at the panel sees: who is asking, Allow or Deny." loading="lazy"><figcaption>What the person at the panel sees: who is asking, Allow or Deny.</figcaption></figure>

  That dialog also has a checkbox, **"Auto accept all connections for next
  5 minutes"** — it's part of MeshCentral's stock consent dialog, and the
  person at the panel can tick it. Leave it unticked unless the shift has
  agreed to it; ticking it waves through every connection request for the
  next five minutes with no further prompt.

  After 60 seconds with nobody answering, the session was refused and
  the browser's Desktop tab returned to **Disconnected** with no screen
  content ever shown — denial-by-timeout **passed** on the bench:

  <figure class="doc-shot"><img src="../../assets/shots/app/remote-view-07-denied.png" alt="Nobody answered within 60 seconds: the session is refused and the Desktop tab shows Disconnected." loading="lazy"><figcaption>Nobody answered within 60 seconds: the session is refused and the Desktop tab shows Disconnected.</figcaption></figure>

  A human actually clicking **Deny** was not separately exercised on the
  bench — only the automatic timeout was — so confirm an explicit Deny
  click also blocks the session the first time you do this for real.
- [ ] **Confirm the Terminal and Files tabs are simply absent** for an
  operator account, not merely disabled — on the bench, an operator's
  browser showed only **General, Desktop, Events**. This was also checked
  server-side, not just in the UI: a restricted account's attempts to open
  a command shell or transfer a file were refused by the server itself with
  `Unable to route` / `Access denied`, so the tabs being hidden reflects a
  real, enforced restriction, not just a UI convenience.
- [ ] **From a PC outside the office LAN range (or outside the firewall
  rule's LocalSubnet scope), confirm you cannot reach the page at all, or
  it answers a bare 401 before any login form.** This is enforced by two
  independent mechanisms — the firewall rule's `LocalSubnet` scope and the
  server's own IP allow-list — but there was no second, genuinely
  off-subnet machine available during the 2026-09-04 bench pass to watch
  this end to end. Treat it as expected by configuration, not yet
  independently observed, until you've watched it fail from a real second
  machine at your own site.

## When something goes wrong {#troubleshooting}

| Symptom | Likely cause | Fix |
|---|---|---|
| Cannot reach the page at all | Office NIC classified **Public**, the rule is managed by GPO and hasn't been added, or the rule is bound to the wrong NIC | Reclassify the NIC to Private/Domain (see [Firewall and network category](#firewall)); ask the domain admin to add the GPO rule; re-run `New-RemoteViewFirewallRule.ps1 -InterfaceAlias` with the correct NIC |
| A plain **"401"** page appears before any login form | The client's IP is outside `userAllowedIP` — including the case where the hostname resolved to the machine's **IPv6** address first, which isn't on the allow-list | Make sure the HMI name resolves to its **IPv4** address for LAN clients (a hosts entry, or fix DNS), or reach it by the IPv4 address directly; otherwise widen `-LanCidr` |
| **"Invalid origin in HTTP request, click to reconnect."** | Browsed by IP address on an older build, or an uppercase/dotless certificate name from a package built before the 2026-09-04 fix (see [Status](#status)) | Browse to `https://<hostname>:8443/` by the exact hostname; if the problem persists, reinstall with the current package |
| **"Unable to access this feature until two-factor authentication is enabled."** | The account hasn't finished authenticator enrolment yet | **My Account → Account security → Manage authenticator app** — see [Right after install](#after-install) |
| Consent prompt at the panel is never answered | By design — an unattended panel denies after 60 seconds | Expected behavior, not a fault; ask the operator to answer promptly next time |
| Device shows **Offline** in My Devices | The Mesh Agent service has stopped, or antivirus quarantined `MeshAgent.exe` / `MeshService64.exe` | Check the **Mesh Agent** Windows service is Running; check the antivirus product's quarantine/detection history and restore plus exclude if needed |
| Installer prints **`ROLLBACK INCOMPLETE`** | A file was locked, or an item this run created could not be removed | Clear the named items by hand, or run `Uninstall-RemoteView.ps1`, before re-running the install |
| PowerShell health-check scripts fail while the browser works fine | A known Windows PowerShell 5.1 trap: `Invoke-WebRequest` / `ClientWebSocket` with a certificate-validation callback throws `"There is no Runspace available to run scripts in this thread"` in a non-interactive host | Use `curl.exe -k https://127.0.0.1:8443/` for a hand check, or just use a real browser — the installer itself already avoids this trap |

## Uninstall {#uninstall}

```powershell
.\Uninstall-RemoteView.ps1            # removes everything
.\Uninstall-RemoteView.ps1 -KeepData  # keeps meshcentral-data + recordings
.\Uninstall-RemoteView.ps1 -Force     # skip the confirmation prompt
```

This removes the **Mesh Agent** service, the **MeshCentral** service, the
`Ring Remote View (HTTPS <port>)` firewall rule, the Start Menu and desktop
shortcuts, and the install root itself. On a bench uninstall it also
removed the **"Mesh Agent WebRTC Traffic"** rule described in
[Firewall and network category](#firewall) — a side effect of the agent's
own uninstall, not something this script does directly. `-KeepData`
preserves `meshcentral-data\` (config, certificates, the account database)
and `meshcentral-recordings\` (the session evidence) instead of deleting
them with everything else. It is idempotent — safe to run again if a
previous attempt didn't finish cleanly.

**Ring is not touched.** The app, its own config, and the PLC connection
are unaffected by any of this — the only thing that disappears is remote
viewing. Uninstalling is always a safe first move if you're trying to rule
out Ring Remote View while troubleshooting anything else on the HMI PC.

## Status and what is still owed {#status}

Everything in this section reflects a bench verification pass on
2026-09-04, on the developer's own laptop — **not** an actual plant or
customer machine. Read it as "this is what has been proven, and what has
not," not as a claim that this package has shipped anywhere yet.

- **Bench-verified:** a full install, the browser walkthrough described
  under [Right after install](#after-install) and
  [Check your work](#verify) as an operator account, and a full uninstall.
  Several of the runbook's own pre-ship penetration-test checks were
  confirmed to fail closed **server-side**, not merely in the UI: file
  transfer, remote command execution, an interactive shell, self-registration
  (disabled outright), and reaching the AMT management port (nothing is
  listening).
- **Two defects were found in this same bench pass, and are fixed in this
  package version:**
  1. An **uppercase** certificate name broke the browser entirely with
     "Invalid origin in HTTP request" — Windows' own computer name is
     always uppercase, but a browser always lowercases the hostname it
     sends, and the two were being compared case-sensitively.
  2. A certificate name with **no dot** in it meant MeshCentral never
     offered the "Account Security" section needed to enrol an
     authenticator — while the domain-wide 2FA requirement blocked every
     device feature until one was enrolled. That combination was a genuine
     dead end with no way out of the UI.

  Both are fixed by rendering the certificate name lowercase and with a
  dot (the machine's real DNS name if it has one, otherwise
  `<hostname>.local`), and by adding an explicit list of allowed browser
  origins.
- **Not yet installed at any actual site.** Every result above comes from
  the bench, on one developer laptop.
- **The runbook's own pre-ship penetration test is a hard gate, and it is
  not fully complete.** Still outstanding, and needing a second machine or
  a clean VM to observe properly: the raw low-level terminal-relay probe
  specifically (only the higher-level "run a shell" path was exercised, not
  the raw protocol path directly); the registry and software-inventory tab
  denial; a view-only account's input actually being discarded rather than
  applied; and reaching the server from a genuinely off-subnet machine. Also
  not exercised even on the bench: a human actually clicking Allow or Deny
  at the panel — only the automatic 60-second timeout-deny was observed.
- **The Inno Setup GUI wrapper has never been compiled.** No
  `RingRemoteView-Setup.exe` exists on any machine that did this work. The
  PowerShell installer in this chapter is the only supported install path
  today.

## Sources verified

- `remote-view/README.md`
- `remote-view/Install-RemoteView.ps1`
- `remote-view/Provision-RemoteView.ps1`
- `remote-view/Uninstall-RemoteView.ps1`
- `remote-view/New-RemoteViewFirewallRule.ps1`
- `remote-view/Build-RemoteViewPackage.ps1`
- `remote-view/config-template.json`
- `docs/production-readiness/REMOTE_ACCESS_RUNBOOK.md`
- `docs/production-readiness/REMOTE_VIEW_BENCH_EVIDENCE_2026-09-04.md` (every bench observation quoted in this chapter: the install output, the browser walkthrough, the server-side denials, the two defects and their fix, the uninstall)